深圳市知用电子有限公司
ShenZhen ZhiYong Electronics Co., Ltd.
CT-300I(300A/DC~100kHz)
CT-300I(300A/DC~100kHz)

Primary peak current ±500A

Precision ±0.5%

浏览次数:678
说明书: 产品说明书

1. Summary

CTI series transducer is used to test on DC, AC and pulse current. The primary side is insulated from the secondary side. The close loop transducer applied Hall theory has high precision, straight linearity, low temperature drift, low insertion loss, and strong anti-interference ability. CTI series have been widely used in the current test of power supply field.

CTI series include CT-050I(50A), CT-100I(100A), CT-200I(200A) and CT-300I(300A). The test aperture diameter is 20 mm, easy to use and reliable.

1、 Product Specification
1.1 Electronical parameter

TypeCT-300I
Primary rated current (RMS)
IPN
300A
Primary peak current
IPM
±500A
Conversion ratio
KN
1:2000
Secondary current
IS
±150mA
Measuring
resistance RM
Range RM min RM max
@±12V IPN 0Ω 30Ω
IPM 0Ω 7Ω
@±15V IPN 0Ω 43Ω
IPM 0Ω 17Ω
DC supply voltage Vc (±5%) ±12V … ±15V(±5%)
Current consumption Ic ≤28mA +IS (@±12V)
Insulation voltage between the
primary and secondary Vd
6kVrms (50Hz /1 min)

 
1.2 Precision-dynamic parameter

TypeCT-300I
Precision XG TA=25℃ ±0.5%
Linearity εL ±0.1%
Zero offset current Io ≤±0.2mA
Magnetic offset current IoM ≤±0.2mA
Temperature offset current IoT (-10℃~70℃) ≤±0.64mA(±0.2mA 典型值)
Response time tr <1us
Current rising rate di/dt >100A/us
Band width (±3dB) BW 100kHz

 

链接链接链接yiqicao17c@gmail.com链接链接链接亚洲永久精品免费www52zCx