深圳市知用电子有限公司
ShenZhen ZhiYong Electronics Co., Ltd.
CPL8100B (100A / 2MHz)
CPL8100B (100A / 2MHz)

Current range 50mA~10A Peak

Typical DC precision 3%±50mA

浏览次数:769
说明书: 产品说明书

1. Summary 

CPL8100A/B is a kind of current probe that can measure both DC and AC current up to 100A (70.7Arms). The band width of CPL8100A is 600 kHz (-3dB), and the band width of CPL8100B is 2MHz (-3dB).CPL8100 series provide two range option of 10A and 100A, the users may choose the correct range according to the current value. The auto zero function make it easy for the users to operate, and it also has power and low voltage indicator as well as overload sound alert. The probe can be powered by battery or external power supply, which makes the measurement a lot more convenient. With standard BNC output port, the probe can connect to any oscilloscope, and it can also connect to multimeter with BNC-banana plug. The CPL8100 series is usually used in  power supply , motor drive and power supply. 

 

Adapter CK-612
BNC Output cable CK-310/320
9V battery

1、Electronic Characteristics
Test Condition: 23℃, 60%RH, cable under test get through the test center, load resistance 1MΩ
 

Range levelLH
Current range 50mA~10A  Peak 1A~100A  Peak
Attenuation accuracy 0.1V/A 0.01V/A
Typical DC precision 3%±50mA 500mA~40A Peak :4%±50mA;40A~100A Peak :±15% Maximum
Band-width
(-3dB)
CPL8100A DC-600kHz Refer to the typical Amplitude frequency characteristic (Figure 1)
CPL8100B DC-2MHz Refer to the typical Amplitude frequency characteristic (Figure 2)
Max current VS frequency
characteristics curve
Figure 3
Phase shift DC~65Hz:<1.5&deg; DC~65Hz:<1&deg;
Typical DC linearity The typical DC linearity at H level(0.01V/A), Figure 4
Rise timeCPL8100A ≤583ns
CPL8100B ≤175ns
Max operation current Please refer to voltage and current rating table
Max operation voltage Please refer to voltage and current rating table
Max floating voltage Please refer to voltage and current rating table
Operating voltage RMS CATI 600V CATII 600V CATIII 300V
Common mode voltage RMS CATI 600V CATII 600V CATIII 300V
Typical battery type and life. 9V alkaline layer-built battery/ 15H
Low power indication When battery voltage is lower than 6.5V, battery indicator will turned red and alert.
Overload indication When the current under test surpasses the range, the buzzer will buzz



                        Figure 2 CPL8100B Typical Gain VS Frequency curve


                              Figure 4 Typical DC linearity (0.01V/A level)